How to solve the internal leakage problem of electric ball valve
Release Time :2021-07-06 16:00  Author: wzxinnet   Browse :734

Electric ball valves sometimes show internal leakage. Let’s talk about several reasons for internal leakage and their common treatment methods. The zero position of the electric ball valve actuator is not set, and it has not reached the fully closed position of the valve. Adjustment method: manually close the valve (make sure that it has been completely closed), then manually close the valve harder, whichever is slightly harder to tighten; then turn it back half a turn (the valve opening direction); then adjust the limit.

Kate professional electric ball valve manufacturer

The selection of the stroke mode of the electric ball valve: the valve is opened and closed by rotating 90°, and the torque of the actuator is not large enough. It is easy to reach the fully closed position when there is no pressure. When there is rotating force, the thrust of liquid propulsion cannot be restrained. , So the closure is not in place. Treatment method: change to a large thrust actuator, or change to a balanced spool to reduce the uneven force of the medium.


Internal leakage caused by the manufacturing quality of electric ball valves: The manufacturer does not strictly control the valve material, processing technology, assembly technology, etc. during the production process, resulting in unqualified sealing surface grinding, pitting, trachoma and other defective products are not eliminated, forming an electric Internal leakage of forged steel ball valve. Treatment method: reprocess the sealing surface. The electric ball valve controls the internal leakage that locally affects the valve. 


The traditional control method of electric ball valve is through mechanical control methods such as valve limit switch and over-torque switch. Because these control elements are affected by the environmental temperature, pressure, and humidity, the valve positioning is inaccurate, the spring is tired, and the thermal contraction coefficient is uneven. And other objective elements, forming the internal leakage of the electric forged steel ball valve. Treatment method: readjust the limit.




CONTACT

Zhejiang Kate Valve Co., Ltd.
24-hour service hotline: 018157792000

TEL: 086-577-67959100 67959200
Mobile phone: 015381559100  015381559200
ADD: No.388,Zhongxin Road,Puxi Industrial Zone,Oubei Town,Yongjia County,Wenzhou

Follow Kaite

Copyright © 2021 Zhejiang Kaite Valve CO.,LTD All Rights Reserved. 浙ICP备11043942号-3 Technical Support : Wzxinnet Sitemap
Close
Online Message